Find the failed emergency light before the power goes out
Emergency lights only matter in the one moment nobody is checking them. Magnifire shows you every light and exit sign, what state it is in now, and how its last discharge test went.
Faults reported by the light itself
Self-testing emergency lights and exit signs know their own condition. Magnifire brings that into the same place as your fire panels: a list of every light, what it is doing now, when its discharge test is due, and whether it passed last time. A failed battery or lamp shows up as a fault, named in plain words, without anyone walking the building with a clipboard.
- Battery, lamp, and mains faults named in plain words
- A discharge test due date for every light, on a six-month cycle
- Filter to what needs attention, or to what is due
- Told by app or SMS when a light fails a test, reports a fault, or goes quiet
Ninety minutes on battery, and a result for every light
The six-monthly test runs each light on its battery for 90 minutes, and it has to still be lit at the end. Each light reports its own result, so you get a pass or a fail per light instead of one tick on a sheet.
A reason, not just a fail
When a light fails its discharge test, Magnifire tells you how long it lasted on battery and what gave out, so the technician arrives with the right part.
History for each light
Every light keeps its own record: each test, each fault, each time it lost mains power and how long it ran on battery before the power came back.
On the site map
Lights sit on your building's plan as pins beside the detectors and extinguishers. Green is healthy, amber has a fault, so a failed fitting is found by looking, not searching.
The test report on file
The report for each discharge test can be downloaded from the test's entry, alongside the pass or fail for every light that took part.
Common questions about emergency lighting
Connected, self-testing emergency lights and exit signs that report their own faults and test results. If your fittings are due for replacement, or you aren't sure what you have, get in touch and we'll talk through what's involved.
The light is switched to its battery and has to stay lit for 90 minutes. It is the six-monthly test for emergency lighting. A quick test, which runs the light on battery for a few seconds to check the lamp and the changeover, is useful but doesn't count towards it.
After hours. A discharge test leaves the batteries flat, and they take about a day to recharge.
No. Emergency lighting inspection and testing is covered by AS/NZS 2293.2, and your records still need to be kept the way that standard and your certifier expect. Magnifire shows what each light reports and when its six-monthly discharge test is due, which makes those records much easier to keep.